E3X-DACS 2M. E3X-DACS 2M. Advanced models. Standard models + Simultaneous determi- nation (2 colors). AND/OR output, Remote setting. Buy OMRON INDUSTRIAL AUTOMATION E3X-DACS 2M online at Newark element Buy your E3X-DACS 2M from an authorized OMRON. Omron E3X-DACS 2M Photoelectric Sensors are available at Mouser Electronics. Mouser offers inventory, pricing, & datasheets for Omron E3X-DAC11 -S 2M.

Author: Mogore Jular
Country: Equatorial Guinea
Language: English (Spanish)
Genre: Photos
Published (Last): 21 October 2012
Pages: 466
PDF File Size: 13.25 Mb
ePub File Size: 11.94 Mb
ISBN: 280-8-52880-141-3
Downloads: 80235
Price: Free* [*Free Regsitration Required]
Uploader: Bataxe

This is a class A product. In a domestic environment this product may cause radio interference in which case the user may s3x required to adequate measures.

There is a possibility of failure and fire. Do not connect sensor to AC power supply. Hot surface may cause heat injury.

Precautions for Safe Use 1 Do not use the Amplifier Unit in a subject to flammable or explosive gases. Be careful when you operate or clean it.

Precautions for Correct Use 1. Power consumption mW max. Switchable normal or reversed display Display orientation Incandescent lamp: Ambient illumination Receiver side Ambient temperature Operating: Groups of 1 to 2 Amplifiers: Short-circuited to 0V or 1. Short-circuited to Vcc xac11 Vcc It is the necessary time to detect a workpiece. Mutual interference prevention does not function in super-high-speed mode.

And, the discrimination mode is only I mode.

E3X-DAC-S Color Sensing Digital Fiber Amplifier Unit/CAD | OMRON Industrial Automation New Zealand

However, I mode is set when difference of the conformity is small or in super-high-speed mode. If the display value changes by light from other sensors, lower the threshold. Stabler detection can be done. When I mode and Black mode is set, the incident light level is displayed instead of the conformity.

E3x-dac11-s E3xdac11s Omron Photoelectric Switch 12-24vdc Ship

It shows how close to the registered color by the value from 0 to Operation indicator Advanced models: Lit when the output is ON. Lit when the output for channel 1 is ON. Lit when I mode is set. Lit when the output for channel 2 is ON. RUN Select to detect actually or to set the following: Manual adjustment of threshold, teaching, zero shift reset, or key lock.

Used to select conformity output or nonconformity output operation. Used to select the channel da11 display or set. Operation mode selector Advanced models: Depend on the setting. DOWN key Decrease the threshold.

October 2016 Discontinuations

Switch the function to be set on the display. LO execute teaching only when OK. The teaching can be executed even in the reverse order. Always attach the Fiber Unit connector end first. If the incorrect end is attached first, the mounting strength will be reduced. Same as SET mode of one point teaching.

  BULLETIN 800T PDF

SET mode display 1 1. Slide the Amplifier Units together and press the Amplifier Units together until they click into place. Same as RUN mode of one point teaching. Press the MODE key for 3 seconds or sac11. Conformity If teaching or sensing is not well done because of shiny of workpieces, tilt the fiber unit by approximately 5 to 20 degrees.

Open the protective cover 2. Press up the lock button. Insert the fibers all the way to the back of the connector insertion opening. Return the lock button to its original position to secure the fibers. Setting Threshold dia Remove xac11 Units in the reverse order.

Brown Brown Pre-wired Models 8. Internal circuits 1 Do not use the Amplifier Unit under the following conditions. If the Amplifier Unit wiring is wired together with or placed in the same duct as high-power lines, inductive noise may cause operating errors or damage the Amplifier Unit. Dca11 the Amplifier Unit and load are connected to power supplies separately, turn ON the power supply to the Amplifier Unit first.

DON nonconformity output The output turns ON when the detected color does not coincide with the registered color or the incident light level is below the threshold. Select either conformity output or nonconformity output operation. Set as the operation mode in SET mode for advanced models. This sheet primarily describes precautions required in installing and operating the product. Before operating the product, read the sheet thoroughly to acquire sufficient knowledge of the product.

For your convenience, keep the sheet at your disposal. Setting the Operation Mode Unit: Protector seal 9 Do not pull or apply excessive pressure or force Power supply connector exceeding 9.

When going to SET mode, this setting will be ignored and the conformity and the threshold will be displayed. Display Conformity Threshold Conformity Threshold The display set by the display switch will return in approximately 5 seconds.

Color sensing type digital fiberoptic amplifier unit [E3X-DAC-S] | OMRON | MISUMI Thailand

Peak level OVER flash twice. The conformity peak level and nonconformity bottom level D-BT Analog bar display. The current detection status is displayed as an analog bar. The bar will lengthen from the right as conformable status is reached.

  ECHOROUKONLINE ALGERIE PDF

Low error Detection status The incident light level is too small. After adjust the Fiber Unit to increase the incident light level, execute re-teaching. Near error Change of the conformity is too small. After adjust the Fiber Unit to increase change of the conformity, dzc11 re-teaching. The function displays are the default settings.

All settings except for the operation mode, timer function and teaching level setting are the same for both channels for advanced models. The values shown for thresholds, conformity, percentages, etc.

Actual displays may vary. Output Setting For the advances models Only Set separately for each channel. Timer Time Setting range: EEPROM error OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the products in the customer’s application or use of the product. Not save Save has been completed. GOOD Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used.

Know and observe all prohibitions of use applicable to this product. See also Product catalog for Warranty and Limitation of Liability.

Pulse width Initial reset: Initialize all of adc11 to return to the default states. Return to the saved states. Disable this function if the external input is turned ON frequently. The write life is approximately writes. C Check an output load and keep current in rating. Check whether the load to be short-circuited. Dsc11 With and Without a Workpiece Error display If a key adc11 pressed while key operations are locked, “LOC ON” will flash twice on the display to indicate that key operations have been disabled.

External Input Setting Not execute user reset If vac11 error occurs, the error messages are blinking as below. In these case Execute following procedures to restore. Output ss the output is ON for both channel 1 and channel 2. Timer Function Timer disabled. Initial reset Output for each channel Set separately for each channel. The output for channel 1 functions according to the detection mode selection.

The threshold displayed in the sub-display is shifted xac11 an amount corresponding to the amount the conformity was changed.